Albatronix logo

Albatronix L.L.C.

Industrial Automation & Engineering

AXLink · Industrial Protocol Gateway

One integration layer for every controller on your plant floor

AXLink bridges Siemens S7, Mitsubishi FX, Unitronics and Advantech ADAM controllers — and is built to keep adding more — into a single Modbus TCP / OPC UA interface. Point any SCADA or HMI at it, legacy or modern, and stop writing one integration per device.

What AXLink Delivers

  • Unified Modbus TCP / OPC UA output
  • Isolated, independent polling per device
  • Zero-downtime configuration changes
  • Built-in diagnostics and live signal monitoring
How It Works

Field protocol in, standard interface out

Field Controllers

S7, ADAM, Unitronics, Mitsubishi FX today — more vendors added as separate driver modules

→

AXLink

One independent polling channel per device, mapped automatically into a shared register table

→

Modbus TCP / OPC UA

One standard interface, ready for legacy or modern SCADA/HMI/historian software

Features

Built for continuous operation, not a demo booth

Isolated Channels

Every protocol keeps its own connection, retry logic and timer — one device going offline never affects another.

Zero-Downtime Configuration

Editing settings restarts only the affected channel — never the polling engine or the Modbus/OPC UA server.

Live Monitor

Every mapped signal in real time, with a text filter and a pinned/favorites list for the tags you check most often.

Built-in Diagnostics

Per-device connection status, retry counters and last-poll timestamps — real data quality, not just a SCADA link check.

Modular Driver Architecture

Each protocol is one self-contained driver module — adding a new one never touches the engine or existing drivers.

Protocols

Growing protocol coverage, one driver at a time

AXLink's driver architecture is built so a new protocol is a single module, not a rewrite. Today's coverage, plus what's next.

Available Today

Siemens S7

Available

Over MPI (PRODAVE6, official Siemens stack) or a built-in Ethernet alternative (S7comm/TCP), switchable per site.

Advantech ADAM

Available

RS-485 I/O modules — digital in/out, analog input — already running in active field deployments.

Unitronics

Available

V-series PLCs via the official Unitronics driver — inputs, outputs, memory bits, integers and timers.

Mitsubishi FX

Available

Programming-port serial protocol (X/Y/M/D/T/C) — verified line-by-line against Mitsubishi's own official protocol manual.

On the Roadmap

EtherNet/IPRockwell / Allen-Bradley
DNP3Common in water/utility SCADA
Modbus RTU PassthroughBridge serial Modbus devices directly
BACnetBuilding automation systems
CANopenMotion and machine-level devices
Omron FINSOmron PLC families
Delta PLCDVP / AS series
LS Electric XGTCnet serial protocol
OPC DALegacy bridge for older OPC clients

Not built yet — listed here because the driver architecture makes each one a scoped, standalone addition. Tell us which protocol matters most for your site.

SCADA & HMI Compatibility

Not locked to legacy platforms

Because AXLink's output is plain Modbus TCP and OPC UA, it works with essentially any SCADA, HMI or historian that speaks either standard — from decades-old installs to today's web-based platforms.

Ignition
AVEVA System Platform
Siemens WinCC Unified
Rockwell FactoryTalk View
GE iFIX
Schneider EcoStruxure
Node-RED / Grafana
InduSoft Web Studio

Listed for compatibility by protocol (Modbus TCP / OPC UA), not vendor partnership. Still on a legacy platform like InduSoft? AXLink lets you migrate the SCADA layer later without re-wiring the field side.

Also Relevant For

Modbus TCP gateway OPC UA server software PLC protocol converter SCADA integration software Industrial IoT gateway Industry 4.0 Legacy PLC modernization Water utility SCADA Multi-vendor PLC integration